KÖHLER ILLUMINATION + 4f IMAGING

6f Optics · Diffraction Orders and Defocus

Follow rays from source to wafer, then explore the pupil and wave results produced by the same diffraction orders.

6f Ray Tracing · Propagation and Pupil Stops

● Order 0● Order +1● Order −1● Higher orders┃ Pupil aperture┄ Blocked rays
Source 0f → Condenser 1f → Mask 2f → Objective 3f → Pupil 4f → Imaging lens 5f → Wafer 6f

Paraxial ray diagram with ideal thin lenses of equal focal length. Rays blocked at the pupil stop there. Best focus z = 0.00 µm

Angle 0.0° · Pitch 551.1 nmPreparing rays and waves…
Higher Orders · Mask and Phase Settings

The default includes orders 0 and ±1. Increasing N adds higher orders to both rays and waves. Ray geometry is paraxial; wave phase follows the selected model. Pupil clock hands show phase including the coefficient sign.

Transmitted nonzero orders—
Michelson contrast over one period—
Current focusz = 0.00 µm

Pupil · Orders and Defocus Phase

Orders, colors and transmission match the 4f ray plane. Signed coefficients are retained when summing fields.

● Order 0● Order +1● Order −1━ Defocus phase / π

Wafer · Intensity I(x) from Wave Interference

Wafer coordinates include the 4f image inversion. Vertical height in the ray diagram becomes the horizontal x coordinate here.

━ I(x) = |E(x)|²┄ MaskIncident intensity = 1

Show Complex Field Re(E), Im(E)

The common illumination carrier is omitted. The same diffraction orders are summed as complex fields before calculating intensity.

━ Re(E)━ Im(E)

Through-Focus Map · Wave Results across Focus

All focus rows share one raw-intensity color scale. The dashed line marks the current focus. This map is not a CD/Bossung curve or measured process DOF.

Expand to calculate the focus map.

0—
Inspect Order Coefficients and Total Phase

Total phase is arg(cⱼPⱼ)/π. Only propagating orders appear in the ray diagram; the table includes all selected orders.

Order jPosition uⱼCoefficient cⱼStatusTotal phase / π

Uniform air medium · One coherent source point · Thin periodic 1D mask. Ideal two-beam focus invariance does not imply infinite DOF for a finite source or resist process.